Repair Guide: ZD-939 Hot Air Rework Station

Problem Description

This article describes how to repair a common failure on the ZD-939 hot air rework station caused by mechanical damage. Require ˜60 Minutes to clean and fix..

Root cause:

  • free flight from ˜80 cm height from the table

After the impact, the device stopped working due to broken solder joints and lifted PCB pads.

Symptoms

  • Device powers but not possible to set the temperature and display is not working
  • Intermittent operation
  • after unscrewing the devise visible damaged on 2x solder joints near transformer area

Technical Background

The failure occurs in the main power section (230V AC) < !!! DANGER !!!>.

Heavy components like the transformer create mechanical stress. After the fall:

  • Solder joints crack
  • Copper pads detach from PCB
  • Electrical connection is lost

Safety Warning

This repair involves mains voltage (230V AC).

  • Disconnect power before opening
  • Do NOT work on live circuits (a burnout in the IT sphere is something different then in the electric area)
  • Ensure proper insulation
  • Risk of electric shock and fire

Required Tools

  • Screw driver Philips
  • Soldering iron
  • Solder (with flux)
  • Copper wire (0.5–1 mm) or component leads
  • Multimeter
  • Optional: heat shrink or hot glue

Repair Procedure

1. Inspect Damage

Identify:

  • Broken solder pads
  • Broken pins
  • Damaged traces
  • Affected pins

2. Trace the Connection

Follow the copper trace from the damaged pad:

  • Find next valid solder point
  • Ensure it belongs to the same electrical path Only connect points on the SAME trace.

3. Create Wire Bridge

  • Prepare short wire
  • Tin both ends
  • Solder:
    • Transformer pin → valid trace point

Keep wire:

  • Short
  • Direct
  • Clean

4. Insulate

  • Cover exposed wire
  • Use heat shrink or glue
  • Avoid contact with other traces

6. Test

Before power on:

  • Check continuity (multimeter)
  • Check for short circuits

Then:

  • Power on carefully
  • Observe behavior

Result

If done correctly:

  • Electrical connection restored
  • Device operational again
Drucken/exportieren